Queen Star Series 10K - 80KVA
- DSP + IGBT technology.
- Output power factor 0.9.
- Active power factor correction in all phases.
- Emergency power off function (EPO).
Розничная цена
0.0
USD
Рыночная цена
0.0
USD
Количество просмотров :
1000
Товарный код
Подкатегория
Высокой частоты онлайн ИБП
Количество
-
+
Наличие на складе :
0
1
Characteristics
Specifications
Downloads
Предыдущий
Queen Star Series 6K - 20KVA
Следующий
Safe Star Series 10K-120KVA
Characteristics
+
Online UPS Queen Star Series 10K-80KVA (3ph in/3ph out)
Key Features:
- True double-conversion.
- DSP technology guarantees high performance.
- Output power factor 0.9.
- Active power factor correction in all phases.
- 50Hz/60Hz frequency converter mode.
- Accepts dual-mains inputs.
- Generator compatible.
- SNMP+USB+RS-232 multiple communications.
- 3-stage extendable charging design for optimized battery performance.
- Adjustable battery numbers.
- Maintenance bypass available.
- Optional N+X parallel redundancy.
Specifications
+
Model | 33Q10KL | 33Q 20KL | 33Q 30KL | 33Q 40KL | 33Q 60KL | 33Q 80KL | Comments |
Input | |||||||
Input voltage | |||||||
Rated voltage | 380VAC/220VAC | 380VAC | |||||
Phase | three phase with ground | ||||||
Turn on voltage range | (120±5~274±5)VAC | (207±9~475±9)VAC | |||||
Bypass voltage range | (60±5~300±5)VAC | (105±9~518±9)VAC | Could be adjusted by software. | ||||
Bypass | 60VAC~220VAC(default 60VAC) | 105VAC~380VAC | |||||
low loss | (default 105VAC) | ||||||
Bypass low comeback | Low loss +5VAC | Low loss +17VAC | |||||
Bypass high loss | 220VAC~300VAC(default 300VAC) | 380VAC~475VAC | |||||
(default 475VAC) | |||||||
Bypass high comeback | High loss -5VAC | High loss -17VAC | |||||
Line low loss | (120±5) VAC /(140±5) VAC | (207±9) VAC /(242±9)VAC | load≤50% | ||||
/comeback | (140±5) VAC /(160±5) VAC | (242±9) VAC /(276±9)VAC | 50%<load ≤90% | ||||
(160±5) VAC /(175±5) VAC | (276±9) VAC /(302±9)VAC | load>90% | |||||
Line high loss/comeback | (275±5)VAC/(260±5)VAC | (475±9)VAC/(449±9)VAC | |||||
Input frequency | |||||||
Rated frequency | 50Hz | ||||||
Frequency | (40~49) ±0.2Hz(default:46Hz) | Could be adjusted by software. | |||||
low loss | |||||||
Frequency | Frequency low loss +0.5Hz | ||||||
low comeback | |||||||
Frequency | (51~60)±0.2Hz(default:54Hz) | ||||||
high loss | |||||||
Frequency high comeback | Frequency high loss -0.5Hz | ||||||
Input power factor | |||||||
Input power factor | > 0.99 | 33Q 10-40KL:220VAC,full R load | |||||
33Q 60-80KL: 380VAC,full R load | |||||||
Generator | Support generator input | Generator rating≥2*UPS rating | |||||
Input current | |||||||
Rated current | 14A | 28A | 42A | 67A | 80A | 105A | |
Input THDI | <= 10% | ||||||
Output protection | |||||||
Rating protection | 32A | 50A | 60A | 80A | 100A | 125A | |
Breaker | Breaker | Breaker | Breaker | Breaker | Breaker | ||
Output power | |||||||
VA/watt | 10KVA/8KW | 20KVA/16KW | 30KVA/24KW | 40KVA/32KW | 60KVA/ | 80KVA/ | |
48KW | 64KW | ||||||
Rated voltage | 220VAC | 380VAC | Sine wave | ||||
Voltage range | 200/208/220/230/240VAC | 345/359/380/397/415 VAC | 33Q 10-40KL: Could be adjusted by software. 10% derating for 208VAC/200VAC. | ||||
33Q 60-80KL: Could be adjusted by software. 10% derating for 345VAC/359VAC. | |||||||
Voltage regulation | ±1% | ||||||
Voltage distortion | ≤5% | ≤10% | Full RCD load | ||||
≤3% | Full R load | ||||||
DC offset | ≤200mV | ||||||
Transient response | ≤9% | R load 0%~100%~0% | |||||
≤6% | R load 20%~100%~20% | ||||||
Transient recovery | ≤60ms voltage recovery to 90% | Full RCD load | |||||
Bypass output | YES | ||||||
before turn-on | |||||||
Crest ration | 3:1 | ||||||
Output frequency range | |||||||
Normal mode | 1,Same as input frequency(46Hz~54Hz) | ||||||
2,50Hz(Input frequency>54Hz or Input frequency<46Hz) | |||||||
Battery mode | (50±0.1) Hz | ||||||
Slew rate | 1 Hz/Sec | ||||||
Efficiency | |||||||
Normal mode | > 93% | > 90% | |||||
Battery mode | > 90% | > 90% | |||||
Overload | |||||||
Normal mode | Overload warning only | 105%±5%≤load | |||||
/battery mode | 1min,then transfer to bypass and alarm. | 105%±5% | |||||
30S,then transfer to bypass and alarm. | 125%±5% | ||||||
300mS, then transfer to bypass and alarm. | load>150%±5% | ||||||
Automatically retransfer | YES | ||||||
Short protection | |||||||
Normal/ | YES | ||||||
battery mode | |||||||
Transfer time | |||||||
Normal to battery mode | 0mS | ||||||
Battery to normal mode | 0mS | ||||||
Normal to bypass mode | <4mS | 0mS | |||||
Bypass to normal mode | <4mS | 0mS | |||||
Battery and charger | |||||||
Battery | |||||||
Rated voltage | 192VDC | 240VDC | 192VDC*2 | 192VDC*2 | 480VDC | ||
Type/Rating | |||||||
Battery quantity | 16 | 20 | 16*2 | 16*2 | 40 | ||
Backup time | |||||||
Protection | |||||||
Low alarm voltage /comeback voltage | (180.8V±4V)/ (188.8V±4V) | (226V±4V)/ (236V±4V) | (180.8V±4V)/ (188.8V±4V) | (226V±4V)/ (236V±4V) | (452V±4V)/ (472V±4V) | 33Q 30KL use two | |
Shutdown voltage/ comeback voltage | 160V±4V/168V±4V | (200V±4V)/ (210V±4V) | 160V±4V/ | (200V±4V)/ (210V±4V) | (400V±4V)/ (420V±4V) | ||
168V±4V | |||||||
DC protection | |||||||
Overcharge protection/ comeback voltage | (249.6V±4V)/ | (312V±4V) (270V±4V) | (249.6V±4V)/ (216V±4V) | (312V±4V) (270V±4V) | (624V±4V) (540V±4V) | ||
(216V±4V) | |||||||
Leakage current | < 500uA | ||||||
Over discharge protection | 14.5h | Could be set by software | |||||
Battery test | |||||||
Battery weak | YES | ||||||
Battery fault | YES | ||||||
Charger | |||||||
Output voltage | (219.2±3)VDC | (277±3)VDC | (219.2±3)VDC | (277±3)VDC | (554±3)VDC | ||
Charge time | Depends on the external battery capacity | ||||||
Charge current | 7.5A | 6A | 5A | 4A | 10A | ||
Interface | |||||||
Alarm silence | YES | ||||||
DC power | YES | ||||||
turn-on | |||||||
Automatically retransfer | YES | ||||||
Audio alarm | |||||||
Battery mode | Beep/4s | ||||||
Battery low/ | Beep/1s | ||||||
charger fault | |||||||
UPS fault | Continue beep | ||||||
Overload | Beep/1s | ||||||
Bypass mode | Beep/2Min | ||||||
L/N inverse | Beep/2Min | ||||||
Communication | |||||||
RS232 interface | YES | ||||||
Intelligent slot | YES | ||||||
Monitor software | Appending with UPS | ||||||
Cooling | |||||||
Force air cooling | |||||||
Display | |||||||
LCD/LED displays UPS status | |||||||
Environment | |||||||
Work temperature | 0℃~40℃ | ||||||
Altitude | <1000m | ||||||
Audible noise | ≤60dB | ||||||
Storage temperature | -15℃~45℃ | ||||||
Work humidity | 20%~95% | ||||||
Standard | |||||||
EMS | |||||||
ESD | IEC61000-4-2 | Level4 | |||||
RS | IEC61000-4-3 | Level3 | |||||
EFT | IEC61000-4-4 | Level4 | |||||
Surge | IEC61000-4-5 | Level4 | |||||
EMI | |||||||
Conducted | EN55022 | Class A | |||||
Radiated | EN55022 | Class A | |||||
Safety | |||||||
Safety | GB4943-2001/IEC62040-1 | ||||||
Machinery features | |||||||
Size | |||||||
Outline dimension and net weight | |||||||
L*W*H (mm) | 710*260*717 | 840*515*1135 | |||||
Net weight(Kg) | 45/93 | 50/98 | 195 | 208 | |||
Optional functions | |||||||
60Hz | Optional | Set by software | |||||
Converter mode | Optional | Set by software | |||||
ECO | Optional | Optional | Available and set by software | ||||
EPO | Optional | Optional | |||||
*Specification is subject to change without further notice |
Downloads
+
сведения
если у вас есть какие - либо полезные советы и замечания по нашей компании или вы хотите проконсультироваться с нашей продукцией, заполните следующий бланк и мы свяжемся с вами в первый раз!
客户留言
Описание:
- 86-755-29610051
- +86-13352908573
- sophiaxie2
- sales@upsen.net
- китай, шэньчжэнь, район Баоань, улица Синьцзянская улица и улица Хо сян Пересечение с центром стороны 1409 - 1410.
сведения
客户留言
Описание:
© 2020 Shenzhen UPSEN Electronic CO., Ltd. All rights reserved. 粤ICP备20055719号