Професионал солутион
Search
Search
Confirm
Cancel
upsen
GT6-10k-(2)
33Q-60-80K
GT6-10k-(2)
33Q-60-80K
名称

Queen Star Series 33Q 10K - 40KVA

● DSP + IGBT technology. ● Output power factor 0.9. ● Active power factor correction in all phases. ● Emergency power off function (EPO).
  • DSP + IGBT technology.
  • Output power factor 0.9.
  • Active power factor correction in all phases.
  • Emergency power off function (EPO).
Розничная цена
0.0
USD
Рыночная цена
0.0
USD
Количество просмотров :
1000
Товарный код
Количество
-
+
Наличие на складе :
0
暂时无货
1
Characteristics
Specifications
Downloads

Online UPS Queen Star Series 10K-40KVA  (3ph in/3ph out)

 

Key Features:

  • Highrfrequency online thre-in and three-out UPS,the output can be conected to unbalanced load,and theinput three-phase always keeps the load balanced.
  • Fully digital control,more stable performance.
  • Energy-saved and environmental protection,efficency is up to 93% Support N+X parallel redundancy
  • The most optimized tower structure design has the smallest volume compared to similar products on the market
  • A single set of battery supplies power to the system,reducing the number of batteries and save cost.
  • 10-20K standard machine integrated design with batterybuilt-in, easy to install and use.
  • Visualized LCD display interface,clear and intuitive display ofthree-phase working information.
  • Intelligent mobile monitoring cards are supported to monitor UPS data in real time through mobile apps
Model 33Q 10KL 33Q 10K 33Q 20KL 33Q 20K 33Q 30KL 33Q 40KL
Rated Power 10KVA/9KW 20KVA/18KW 30KVA/27KW 40KVA/ 36KW
Input Phase 3 Phase 4Wires and Ground
Rated Voltage 380 / 400 / 415Vac
Voltage Range 207 ~ 475 Vac
Frequency Range 40 - 70Hz (Settable)
Power Factor ≥ 0.99
Current THD ≤3% (100% nonlinear load)
Output Phase 3 Phase 4Wires and Ground
Rated Voltage and Accuracy 380Vac(1±1%3P4W+G
Power Factor 0.9
Rated Current 15A 30A 45A 61A
Output Frequency 46-54Hz synchronize with mains power;
50Hz(Mains power between 40-46Hzand 54-60Hz);
50Hz(Battery)
Output Harmonic Wave ≤3% Full R Load)
Current Factor 3:1
Output Overload 105%±5%<Load≤125%±5%: Convert to bypass output and alarm after 1min;
125%±5%<Load≤150%±5%: Convert to bypass output and alarm after 30s;
Load>150%±5%: Convert to bypass output and alarm after 300ms.
Efficiency 92% 91%
Battery Voltage 192VDC ±192VDC
Quantity 16 32
Charge Current(A) 5.5A 1A 7.5A 1A 5.5A
Conversion time between Mains Power and Battery 0ms
Protection ShortCircuit Hold Whole System
Overheat Line Mode: Switch to Bypass;            Backup Mode: Shutdown UPS immediately
BatteryLow Alarmand Switch off
Self-diagnostics up on Power On and Software Control
EPO(optional) Shutdown UPS immediately
Battery Advanced Battery Management
NoiseSuppression Complies with EN62040-2
Alarms Audible &Visual Line Failure,Battery Low,Overload, System Fault
Display Status LED& LCD Line Mode, Bypass Mode, Battery Low, Battery Bad, Overload & UPS Fault
Reading On the LCD Input Voltage, Input Frequency, Output Voltage, Output Frequency, Load Percentage, Battery Voltage & Inner Temperature
ComunicationInterface RS232 , EPO(Standard);   Intelligent slot and SNMP Card(Optional),Relay card(Optional)
Operating Environment Operating Temperature 0 ~ 40
Storage Temperature -25 ~ 55
Audible Noise ≤ 60 dB
Altitude <1500m.When>1500m,lowerthe rated powerforuse
Humidity 20%  95% non condensing
Dimension Machine Size - W*D*H(mm) 260*533*501 260*560*717 260*710*717 260*710*717
Package Size - W*D*H(mm) 350*603*631 436*708*861 350*778*864 350*778*864 350*778*864 350*778*864
Net Weight(KG) 26 72 57.5 98 58.5 63
Gross Weight(KG) 36 82 73 113 74 77
Safety Conformance CE, EN / IEC62040-2, EN / IEC62040-1-1
*Specification are subject to change without prior notice
Characteristics +

Online UPS Queen Star Series 10K-40KVA  (3ph in/3ph out)

 

Key Features:

  • Highrfrequency online thre-in and three-out UPS,the output can be conected to unbalanced load,and theinput three-phase always keeps the load balanced.
  • Fully digital control,more stable performance.
  • Energy-saved and environmental protection,efficency is up to 93% Support N+X parallel redundancy
  • The most optimized tower structure design has the smallest volume compared to similar products on the market
  • A single set of battery supplies power to the system,reducing the number of batteries and save cost.
  • 10-20K standard machine integrated design with batterybuilt-in, easy to install and use.
  • Visualized LCD display interface,clear and intuitive display ofthree-phase working information.
  • Intelligent mobile monitoring cards are supported to monitor UPS data in real time through mobile apps
Specifications +
Model 33Q 10KL 33Q 10K 33Q 20KL 33Q 20K 33Q 30KL 33Q 40KL
Rated Power 10KVA/9KW 20KVA/18KW 30KVA/27KW 40KVA/ 36KW
Input Phase 3 Phase 4Wires and Ground
Rated Voltage 380 / 400 / 415Vac
Voltage Range 207 ~ 475 Vac
Frequency Range 40 - 70Hz (Settable)
Power Factor ≥ 0.99
Current THD ≤3% (100% nonlinear load)
Output Phase 3 Phase 4Wires and Ground
Rated Voltage and Accuracy 380Vac(1±1%3P4W+G
Power Factor 0.9
Rated Current 15A 30A 45A 61A
Output Frequency 46-54Hz synchronize with mains power;
50Hz(Mains power between 40-46Hzand 54-60Hz);
50Hz(Battery)
Output Harmonic Wave ≤3% Full R Load)
Current Factor 3:1
Output Overload 105%±5%<Load≤125%±5%: Convert to bypass output and alarm after 1min;
125%±5%<Load≤150%±5%: Convert to bypass output and alarm after 30s;
Load>150%±5%: Convert to bypass output and alarm after 300ms.
Efficiency 92% 91%
Battery Voltage 192VDC ±192VDC
Quantity 16 32
Charge Current(A) 5.5A 1A 7.5A 1A 5.5A
Conversion time between Mains Power and Battery 0ms
Protection ShortCircuit Hold Whole System
Overheat Line Mode: Switch to Bypass;            Backup Mode: Shutdown UPS immediately
BatteryLow Alarmand Switch off
Self-diagnostics up on Power On and Software Control
EPO(optional) Shutdown UPS immediately
Battery Advanced Battery Management
NoiseSuppression Complies with EN62040-2
Alarms Audible &Visual Line Failure,Battery Low,Overload, System Fault
Display Status LED& LCD Line Mode, Bypass Mode, Battery Low, Battery Bad, Overload & UPS Fault
Reading On the LCD Input Voltage, Input Frequency, Output Voltage, Output Frequency, Load Percentage, Battery Voltage & Inner Temperature
ComunicationInterface RS232 , EPO(Standard);   Intelligent slot and SNMP Card(Optional),Relay card(Optional)
Operating Environment Operating Temperature 0 ~ 40
Storage Temperature -25 ~ 55
Audible Noise ≤ 60 dB
Altitude <1500m.When>1500m,lowerthe rated powerforuse
Humidity 20%  95% non condensing
Dimension Machine Size - W*D*H(mm) 260*533*501 260*560*717 260*710*717 260*710*717
Package Size - W*D*H(mm) 350*603*631 436*708*861 350*778*864 350*778*864 350*778*864 350*778*864
Net Weight(KG) 26 72 57.5 98 58.5 63
Gross Weight(KG) 36 82 73 113 74 77
Safety Conformance CE, EN / IEC62040-2, EN / IEC62040-1-1
*Specification are subject to change without prior notice
Downloads +

смежная продукция

Информация о содержании временно не отображается
Добавьте данные в записи в фоновом режиме。

сведения

 

если у вас есть какие - либо полезные советы и замечания по нашей компании или вы хотите проконсультироваться с нашей продукцией, заполните следующий бланк и мы свяжемся с вами в первый раз!

Название приложения к сообщению:
客户留言
Описание:
wx wx wx wx wx

сведения

Название приложения к сообщению:
客户留言
Описание:
© 2020 Shenzhen UPSEN Electronic CO., Ltd. All rights reserved. 粤ICP备20055719号 made-in-china